ECM Group Seal Group Gasket (73x57x8mm) – Original
Original ECM Group Gasket Seal
Part Number C449900229
Maintenance
Please note: the below maintenance guideline is taken from the ECM Puristika, but the application is similar to all ECM machines.
Replacing the group gasket C449900229 and the shower screen C519900103 must be changed at the same time.
- Switch off the machine (power switch in lower position) and disconnect the power cord.
- Open the steam valve and release the steam. Then close it again.
- Let the machine cool down to room temperature.
Follow the steps as indicated below:
- Brew group in the beginning.
- Use a flat screwdriver to pry out the shower screen and the group gasket.
- The shower screen and the gasket are now nearly removed.
- Remove the shower screen and the gasket completely.
- Keep the new spare parts ready at hand (the rounded side of the group gasket with ECM print facing upwards to the brew group).
- Clean the brew group with a brush. Lock the shower screen firmly into the gasket.
- Insert the shower screen into the brew group.
- Take the portafilter without filter.
- Clamp the portafilter into the brew group.
- Then, move the portafilter until the shower screen is locked firmly into the gasket.
- Now you can easily lock the portafilter into place.
- The group is ready for use.